PV inverter busbar

The structure is compact, which can optimize the space structure more reasonably

1. Low inductance, can effectively reduce peak voltage and protect electronic components such as IGBT 2. Low impedance and good heat dissipation efficiency reduce system temperature rise 3. The structure is compact, which can optimize the space structure more reasonably 4. Convenient installation and maintenance, durable 5. Flexible input and output modes, which can be well integrated with connectors, fasteners, cables, etc.

Return list

Product introductionApplication areaModel description

continuously  working current: 10-2000A;

continuously working voltage: 380-5000V

continuously endurance temperature: -40~105℃ (different insulation materials have different temperature resistance, see model description)

Insulation resistance: 20MΩ DC1000V RH≤90% 

Flame retardant rating: UL94-V0

Creepage distance: refer to national standard and design according to working voltage

Structural features: simple structure, flat or slightly bent

Single conductor thickness: 1-3mm 

product advantages:

1. Low inductance, can effectively reduce peak voltage and protect electronic components such as IGBT

2. Low impedance and good heat dissipation efficiency reduce system temperature rise

3. The structure is compact, which can optimize the space structure more reasonably

4. Convenient installation and maintenance, durable

5. Flexible input and output modes, which can be well integrated with connectors, fasteners, cables, etc.

Insulation process:

Insulation paper hot press edge banding

ProductSeries

2cores12mm

2cores10.3mm

2cores8.0mm

HV800

2cores6.0mm

HV580

3coresHV280

2coresK28

2coresK28AngleSocket

Current Max 250A 250A 200A 200A 130A 35A 23A 23A 23A
800V 1000V 1000V 800V 800V 800V 800V 800V 800V 800V
Hole position 2 2 2 2.3 2 2.3.4 3 2 2
Shell material ADC12 PA66 ADC12 PA66 ADC12 ADC12 ADC12 PA66 PA66
HVIL
Shielding
IP67,IP6K9K
Anti-touch IP2XB
Wire diameter (mm²) 35,50,70 50,70 35,50 25,35,50 16,25,35 2.5 ,4,6 2.5 ,4 2.5 ,4 2.5 ,4
Error proofing A,Y A,Y,Z,U A,Y,Z,U A,Y,Z A,Y,Z A,Y,Z,U,V A,B A,Y,Z,U,V A,Y,Z,U,V
Outbound direction 90°,180° 90°,180° 90°,180° 90°,180° 90°,180° 180° 180° 180° 90°
Cable type Single core shielded cable Single core shielded cable Single core shielded cable Single core shielded cable Single core shielded cable Single core shielded cable Single core shielded cable Single core shielded cable Single core shielded cable